adp series power adapters 12v 25w/36w/66w technical d at asheet adp 12 v highligh ts & features energy star compliance (level vi ) it safety approvals 100k hours mtbf over - voltage/load/temperature & short circuit protections model information adp series power adapters model number input v oltage range output v oltage output cur r ent adp - 25fw b b 90 - 264vac 12 vdc 2.1a adp - 36ph b h 90 - 264vac 12 vdc 3 a adp - 66cr b e 90 - 264vac 12 vdc 5.5 a specifications input ratings / characteristics 25w 3
w
w nominal input voltage 115/230vac 100 - 240vac 115/230 va c input voltage range 90 - 264 vac nominal input frequency 50 - 60hz input frequency range 47 - 63hz input current 1a max @ 100vac 600ma @ 240vac 1a max at 100vac input voltage 2 a max at 100vac input voltage inrush current(cold start) <50a at 120vac no damage at 240vac <90a at 230vac efficiency at nominal input voltage 86% @ 115vac 84% min, max load and measured at the end of dc cable. 8 3 % active mode efficiency @ 115vac 86.38% > 87.4% 88% active mode efficiency @ 230vac n/a >84.78 88% no load power consumption <0.1w @115vac <0.1w @ 115vac/60hz and 230vac/50hz 0.21w hold up time at maximum load >16.7milliseconds@115vac >20 milliseconds@230vac 5milliseconds@100vac 10milliseconds minimum at 100vac/50hz.
adp series power adapters 12v 25w/36w/66w technical d at asheet output ratings / characteristics 25w 3
w
w rated voltage 12v voltage range(all models) 11.4 ~ 12.6v current 0 - 2.1a 0 - 3a 0 - 5.5a output ripple and noise @20mhz. bw, with 0.1uf ceramic and 47uf electrolytic caps connected parallel to load. <120mvp - p 450mv pk - pk 120mv pk - pk turn on delay time 2 seconds @ 120vac 5 seconds @ 100 - 240vac 3 seconds @ 90vac/60hz a nd - 0 ? to +45 ? ; or 10 seconds at - 20 ? to 0 ? . rise time <20ms 30ms 30ms max load capacitance (microfarads) 1000 470 1000 load transient response 0% - 50% - 0% and 50% - 100% - 50% of full nominal load. freque ncy is 60hz, 50% duty cycle and the slew rate shall be at 0.02a/us. 0.1~1.5a & 1.5a~3a load at 2.5a/us slew rate , 50% duty cycle , frequency be operated 100hz ~ 10khz 25 % step load change at 1 a/s.at frequency 500hz with 50% duty. environment , emi and immunity 25w 3
w
w operating temperature 0 c to +40 c - 20 ? to +45 c shipping/storage temperature - 20 c to +75 c - 30 c to +80 c - 40 c to +85 c operating humidity up to 95% 8% to 90% rh (non - condensing) 10% to 95% rh (non - condensing) shipping/storage humidity 5% to 95% rh (non - condensing) 10 - 95% rh (non - condensing) operating altitude maximum of 3700 meters (12000 feet) maximum of 5000 meters - 150 to 3000 meters ( - 500 to 10000 feet) lightning surge immunity per iec - 1000 - 4 - 5 l - n, l - g, n - g, ieee c62.41.2 , 0.5 s 100 khz ring wave , 1.2/50 ? - 8/20 ? combination wave 6kv, criterion b line neutral 1kv/1.2 * 50us level 3 criteria a l - n, l - g, n - g combination wave 6kv, criterion b electric fast transients (eft) en61000 - 4 - 4 +/ - 1kv on input power lines; criterion b i ec - 1000 - 4 - 4/1995 (en 61000 - 4 - 4) level 3 requirements en61000 - 4 - 4 +/ - 1kv on input power lines; criterion b electrostatic discharge (esd) per iec - 61000 - 4 - 2 contact discharge ?kv air discharge ?5kv +/ - 8kv air discharge; +/ - 6kv contact discharge; dielectric withstand voltage (hi - pot) 3kv ac rms from ac input to output leakage current <250ua at 264 vac <100ua at 240vac/50hz <250ua at 264 vac insulation resistance the insulation resistance shall be not less than 4 m ohms after application of 500vdc/10ma for 1 minute. the insulation resistance shall be not less than 30m ohms after application of 500vdc/10ma for 1 minute. the insulation resistance shall be not less than 1 0m ohms after application of 500vdc/10ma for 1 minute. electromagnetic interference (emi) cispr 22/en55022 class b. (a) fcc class b (b) cispr 22 class b (c) vcci class b cispr 22 : 1997/en55022(1998) class b. mtbf 200, 000 hours of continuous operation at 25 80,000 hours of continuous operation at 25 150,000 hours of operation at 90% confidence level at 25degc electrolytic capacitor operating life 7 years at 115vac, 40c and 100% rated load 3 years at 115 vac and 230 vac, and 25degc 100% rated load 5 years at 115 vac and 230 vac, and 25degc 100% rated load
adp series power adapters 12v 25w/36w/66w technical d at asheet protections 25w 3
w
w overvoltage <150% of nominal output voltage (recovery mode) latch mode latch mode overload / overcurrent <150% maximum load current (recovery mode) auto - recovery auto - recovery over temperature recovery mode latch mode auto - recovery short circuit recovery mode auto - recovery auto - recovery mechanical 25w 3
w
w color black outline dimensions (l x w x d) 102 * 36.8 * 49 mm 89.5.0 * 37.0 * 26.5 mm 132 * 62 * 34.1 mm ac inlet type fixed 2 pin ac blades socket c6 type socket c14 type dc cable type ul 2468 #awg 20 ul1571 #awg17 ul1571 #awg1 4 dc cable length 1500 mm 1800 mm 1500 mm dc connector - od 2.1 mm 4.75 mm 2.5 mm dc connector - id 5.5 mm 1.7 mm 5.5 mm dc connector - length 10.5 mm 12.5 mm 9.5 mm mechanical adp - 25fw bb
technical d at asheet adp series power adapters 12v 25w/36w/66w www. deltapsu .com ( january 201 6 , rev. 1.0 ) 4 adp - 36ph bh adp - 66cr be
|